Product Code: LBNY-0005-12600073
Categories: Automation Control System Lab
Simulated Controlled System allows the simulation of different processes,such as: 1st and 2nd order processes, integral action processes, proportional action processes, double integral action processes.
Technical Features:
Power supply: +15 V ; 0 V ; Â15 V
Coefficient of the proportional action of the process KP =
0.2 (attenuation) ....1.5 (amplification)
Time constant T1 = 0.1 .... 1000 s
Time constant T2 = 0.1 .... 1000 s
Input summing point for controlling variable (y) and noise variable (z).
Signal voltage range: Â10V, ..., +10V
Reset input for the restoration of the initial conditions.
Led indicators of over range.
Coarse setting through rotary switches.
Potentiometer fine setting.