Vital signs monitors are used to measure basic physiologic parameters and track the status of low-acuity patients (patients found in medical-surgical areas, emergency departments, and ambulatory care centres) so that clinicians can be informed of changes in a patient's condition.
Patient vital signs monitor, 6 parameters, suitable for adults, paediatric/infants and newborn patients.
Monitoring 6-parameters: ECG and Heart Rate (HR), Respiratory Rate (RR), SpO?, non-invasive blood pressure, and Temperature.
Adjustable signal amplitude and sensitivity.
Colour flat panel display ≥ 10.4 inches.
Multi-waveform and parameters visualization, up to 7 wave forms simultaneously.
Ability to remove unwanted parameters from display.
Defibrillator sync and protection.
Patient information and trend internal database.
Ability to save a minimum of 72 events.
Trend storage ≥ 24 hours.
Data and network interface, LAN, USB or equivalent.
Suitable for standard bed/wall rail and pole stand mount.
Robust design for use in demanding environment.
Designed for frequent and easy dismount and disinfection with hospital-grade products.
Automatic self-test and continuous system monitoring.
Built-in rechargeable battery, autonomy of at least 2 hours.
Automatic switch to battery in case of power failure, automatic recharge on connection to mains.
ain cable at least 3 meter long.
Electrical protection provided by fuses in both live and neutral supply lines.
Power requirements: 100 - 240 Volts - 50/60 Hz (not necessarily in a single unit).
RESPIRATION RATE (RR)
The adult RR measurement range is equal to or better than: 6 – 120 bpm.
The paediatric/neonatal RR measurement range is equal to or better than: 6 – 150 bpm.
68.1 Select your answer from the below drop-down menu.
68.2 Indicate here the actual specification of the offered unit.
The resolution of the RR is equal to or better then: 1 bpm.
ELECTROCARDIOGRAM (ECG) AND HEART RATE (HR)
The ECG is derived from a minimum of 5-leads I, II, III, aVR, aVL, aVF, V.
The unit allows for a simultaneously display of a minimum of 2 ECG traces.
The accuracy of the HR is equal or better than ± 1 bpm or 1%.
The resolution of the HR is equal or better than: 1 bpm.
The unit provides for S-T analyses on ECGs.
The unit provide for arrhythmia analysis on the ECGs.
The unit is equipped with a standardising marker at 1 mV.
The adult HR measurement range is equal to or better than: 15 – 300 bpm.
The paediatrics/neonates HR measurement range is equal to or better than: 30 – 300 bpm.
TEMPERATURE (T)
The temperature measurement range is equal to or better than: 0 - 50°C.
The temperature resolution is equal to or better than: 0.1°C or better.
The temperature accuracy is equal to or better than: ± 0.1°C.
OXYGEN SATURATION (SPO?)
The SpO? measurement range is equal to or better than: 1 – 100%.
The resolution of the SpO? is equal to or better than: 1% or better.
The accuracy of the SpO? is equal to or better than: ± 3% between 70% - 100%.
The HR detection range derived from the SpO? is equal to or better than: 25 – 250 bpm.
The accuracy of the HR detection is equal to or better than: ± 2 bpm or ± 2%, whichever is greater (static).
ALARM FUNCTIONIONALITIES
The unit provide audio-visual alarms for all monitored parameters
The unit allows for user pre-set of high and low alarms for all monitored parameters for each different patient category.
The alarm has override and temporary silence functions.
The unit generates alarms for leads-off or sensor disconnect or sensor failure.
The unit is provided with an apnoea alarm.
The unit is equipped with an alarm for AC status and low battery.
NON-INVASIVE BLOOD PRESSURE (NIBP)
The NIBP is measured through the oscillometric step deflation method.
The unit supports manual and automatic modes.
The unit allows for adjustable inflation pressure.
The NIBP adult range in minimum diastolic and maximum systolic values should be equal or better than: 10 – 270 mmHg.
The NIBP paediatric NIBP measurement range in minimum diastolic and maximum systolic values should be equal or better than: 10 – 200 mmHg.
The BP neonatal measurement range in minimum diastolic and maximum systolic values should be equal or better than: 10 – 135 mmHg.
The resolution of the NIBP is equal to or better than: 1 mmHg or better.
The minimum average error for the NIBP is: ±5 mmHg (0.7 kPa), Standard deviation: ≥ 8 mmHg (1.1 kPa).
SUPPLIED WITH
Instructions for assembly, use and maintenance in English.
1 x Plastic protective dustcover.
1 x set of spare fuses, if required.
1 x wall mount bracket.
1 x spare rechargeable battery pack.
ECG accessories:
- 2 x sets of electrodes (1 x neonatal/paediatric, 1 x adult).
- 2 x sets of patient cable terminals (1 x neonatal/paediatric, 1 x adult).
Temperature sensors:
- 2 x skin temperature probes including cable.
NIBP accessories:
- 3 x blood pressure cuffs (1 x neonatal, 1 x paediatric, 1 x adult).
- 3 x NIBP hoses (1 x neonatal, 1 x paediatric, 1 x adult).
SpO? transducers, including connection cable:
- 3 x neonatal size, reusable clip-on type.
- 10 x neonatal size, single-use, wrap-around type.
- 2 x adult size, reusable clip-on type.
- 2 x paediatric size, reusable clip-on type.
Request a custom quote, full technical datasheet, or place a bulk / tender enquiry. Our specialists will get back to you within 1 business day with pricing, lead time, and export documentation.
As one of India's leading Monitor,patient,portable,w/access manufacturers, suppliers & exporters, we deliver tender-grade quality with documented compliance to institutions, laboratories & training facilities across 65+ countries.
Every Monitor,patient,portable,w/access unit is manufactured to international quality standards and tested before dispatch. Full QC documentation & calibration certificates included.
Established export channels across Africa, Asia, the Middle East & beyond. Complete shipping documentation — certificates of origin, packing lists, test certificates, customs paperwork.
Need a specific configuration of Monitor,patient,portable,w/access? We offer customisation for tender specifications, OEM branding, voltage variants & bulk institutional orders.
Technical consultation before purchase, installation guidance, operator training documentation, and responsive after-sales support — backed by our specialist engineering team.
Trusted by institutions, governments & industries worldwide for reliable, tender-documentation-ready supply.
We supply Monitor,patient,portable,w/access across seven major buyer segments worldwide:
Practical laboratory training & coursework experiments
STEM education & physics / chemistry / biology demos
Process quality, testing & calibration requirements
Clinical lab, diagnostics & pathology applications
Ministry, defence research & PSU lab infrastructure
UNICEF, WHO, UNDP & bilateral aid procurement
Skill development & technical training labs
Direct & sub-contractor tender fulfilment
Manufacturing scale & global reach
Documentation-ready supply for tender-grade procurement — certificates of origin, test certificates, calibration data & compliance matrices.
Laboratory Instrument India is a recognised manufacturer, supplier and exporter of Monitor,patient,portable,w/access from India. We supply this product across our complete export network — from individual institutional purchases to large-scale tender supply contracts.
Nigeria, Kenya, Ghana, Ethiopia, Tanzania, Uganda, South Africa, Egypt, Morocco, Algeria, Senegal, Cameroon
Bangladesh, Sri Lanka, Nepal, Myanmar, Vietnam, Indonesia, Philippines, Malaysia
UAE, Saudi Arabia, Oman, Qatar, Kuwait, Iraq, Jordan
All shipments include complete export documentation, customs paperwork & freight handling.
Common questions from buyers, procurement officers & technical evaluators about ordering, customisation, lead time & documentation.
Speak directly with a product specialist for technical clarifications, custom configurations & bulk tender pricing.