Bacterial Growth Incubator (5oC to 80 oC)
Need to be suitable for incubation of different strain of microbial organisms, on different media plates, and also for conditioning of heat sensitive media and to provide an optimal, homogeneous, temperature uniformity and stability to ensure that protocols (pharmacopeia standards e.g. USP,BP, Ph. Eur) are fully reproducible
Technical Specifications:
Material of construction
Double walled construction with complete inner chamber made of corrosion resistant stainless steel
Outer chamber is of steel sheet finished with powder coated point insulation to maintain desired temperature or with better design and construction
Inner glass door ( non fragile or durable)
Inner chamber is fabricated with ribs for adjusting shelves to convenient height and shelves to be supplied
Shelves is made of polished stainless steel sheet as per chamber
Set temperature range in °C
5°C up to +80°C
Temperature is thermostatically controlled
Temperature is thermostatically controlled with range 1
Temperature homogeneity between top and bottom shelves is maintained by forced circulation
Need to be equipped with data logger for continuous/regular temperature monitoring, with a print out
Setting resolution temperature is 0.1 °C
Timer and control
Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
Need to be equipped with data logger for both time and temperature reading with a print out
Function set point wait
The process time does not start until the set temperature is reached
Calibration
Works calibration certificate for 5 temperatures including: +37 °C, +52 °C, +70 °C
Standard works calibration certificate (measuring point chamber centre) at +37 °C"
Adjustable parameters
Temperature (Celsius or Fahrenheit), air flap position, program time, time zones, summertime/wintertime
Communication
Need to be supported with software for reading out, managing and organizing the data logger via Ethernet interface (temporary trial version can be downloaded). Need to be supported with USB stick software control and required accessories
Temperature control
adjustable electronic(thermostatic) over temperature monitor and mechanical temperature limiter to switch off the heating 20°C above nominal temperature
Door
Fully insulated stainless steel door design
Volume 200- 260 L with better design
Dimensions:
Width: 200 to 300 mm
Height: 500 to 700 mm
Depth 700 to 900 mm
Net Wet 100-150 kg
Operating Environment;
Temperature:+10 °C to + 32°C
Relative humidity : Not more than 85%
Altitude:- 2300-2400 meter
Utility requirement:
Voltage: 220VAC, + 10% , 50Hz.